[1]杨国雄,李文飞,邓庆祥.深圳机场二次雷达站防雷地网整改工程设计分析[J].气象研究与应用,2015,36(02):120-122.
Yang Guo-xiong,Li Wen-fei,Deng Qing-xiang.Analysis on lightning protection ground improvement engineering design of secondary radar station in Shenzhen airport[J].Journal of Meteorological Research and Application,2015,36(02):120-122.
点击复制
深圳机场二次雷达站防雷地网整改工程设计分析()
气象研究与应用[ISSN:1673-8411/CN:45-1356/P]
- 卷:
-
第36卷
- 期数:
-
2015年02期
- 页码:
-
120-122
- 栏目:
-
防雷技术及其他
- 出版日期:
-
2015-12-21
文章信息/Info
- Title:
-
Analysis on lightning protection ground improvement engineering design of secondary radar station in Shenzhen airport
- 作者:
-
杨国雄; 李文飞; 邓庆祥
-
广东天文防雷工程有限公司, 广东广州 510080
- Author(s):
-
Yang Guo-xiong; Li Wen-fei; Deng Qing-xiang
-
Guangdong Astronomical Lightning Protection Engineering Co., LTD, Guangdong Guangzhou 510080
-
- 关键词:
-
接地模块; 工频接地电阻; 土壤电阻率; 长效降阻剂
- Keywords:
-
grounding module; industrial frequency grounding resistance; earth resistivity; resistance reducing agent
- 分类号:
-
P427.32
- 摘要:
-
通过对深圳机场二次雷达站地网整改工程设计施工过程进行分析,采用增设非金属接地模块、在地网中释放长效降阻剂等降阻措施相结合的方式,最终测试结果达到了设计要求;给防雷接地设计施工人员提供一些经验参考。
- Abstract:
-
Based on analysis of lightning protection ground improvement engineering design of secondary radar station in Shenzhen airport, the final test results meet the design requirements by adding the number of non-metal grounding module and releasing constant resistance reducing agent into the ground resistance reduction measures to provide some reference experience for grounding design and construction personnel.
备注/Memo
- 备注/Memo:
-
收稿日期:2015-02-18。
作者简介:杨国雄(1960-),男,工程师,现主要从事雷电防护工作。
更新日期/Last Update:
1900-01-01