[1]黎勋,魏建军,罗雁飞,等.广西大气负离子观测系统运行分析评估[J].气象研究与应用,2023,44(03):114-118.[doi:10.19849/j.cnki.CN45-1356/P.2023.3.20]
 LI Xun,WEI Jianjun,LUO Yanfei,et al.Analysis and evaluation of the operation of the atmospheric negative ion observation system in Guangxi[J].Journal of Meteorological Research and Application,2023,44(03):114-118.[doi:10.19849/j.cnki.CN45-1356/P.2023.3.20]
点击复制

广西大气负离子观测系统运行分析评估()
分享到:

气象研究与应用[ISSN:1673-8411/CN:45-1356/P]

卷:
第44卷
期数:
2023年03期
页码:
114-118
栏目:
出版日期:
2023-09-15

文章信息/Info

Title:
Analysis and evaluation of the operation of the atmospheric negative ion observation system in Guangxi
作者:
黎勋1 魏建军2 罗雁飞3 苏禹宾1 殷智4 王玮1
1. 广西壮族自治区气象技术装备中心, 南宁 530022;
2. 马山县气象局, 广西 马山 530600;
3. 玉林市气象局, 广西 玉林 537000;
4. 桂林市气象局, 广西 桂林 541001
Author(s):
LI Xun1 WEI Jianjun2 LUO Yanfei3 SU Yubin1 YIN Zhi4 WANG Wei1
1. Guangxi Meteorological Technology Equipment Center, Nanning 530022, China;
2. Mashan Meteorological Bureau, Guangxi Mashan 530600, China;
3. Yulin Meteorological Bureau, Guangxi Yulin 537000, China;
4. Guilin Meteorological Bureau, Guangxi Guilin 541001, China
关键词:
大气负离子运行情况故障配件类型故障分布
Keywords:
atmospheric negative ionsoperationtype of faulty accessoriesfault distribution
分类号:
P413
DOI:
10.19849/j.cnki.CN45-1356/P.2023.3.20
摘要:
选取广西大气负离子观测系统2021年逐小时观测数据资料,分析评估观测数据到报情况以及针对系统故障提出改进对策建议。结果表明,广西大气负离子观测系统站点运行正常数为15个,出现较长时间离线状态为15个,该系统30个站点到报率平均值为76.42%,数据可用性平均值为50.94%。负离子观测系统故障配件占比最高为风扇,故障率为38%。系统配件发生故障次数最多为22次;贺州和阳朔站申领备件数最多(均为6件),有9个站未申领过备件。并从考核机制、维护管理、数据评估等方面提出提高系统整体运行质量建议。
Abstract:
This paper selected the hourly observation data of Guangxi atmospheric negative ion observation system in 2021, and analyzed the arrival of observational data and to propose improvement countermeasures against the system failures. The results showed that the number of stations operating normally was 15, and the number of offline stations for a long time was 15. The average arrival rate of 30 stations was 76.42%, and the average data availability was 50.94%. The highest percentage of faulty components of the negative ion observation system was the fan, with a failure rate of 38%. The highest number of system parts failure was 22 times. Hezhou and Yangshuo stations had the largest number of spare parts, boths of which were 6, and 9 stations had not applied for spare parts. This paper also puts forward suggestions to improve the overall operation quality of the system from the aspects of assessment mechanism, maintenance management and data evaluation.

参考文献/References:

[1] 阚莉,陈明.空气中负氧离子研究现状[J].资源节约与环保,2015(7):123.
[2] 毛成忠,于乃莲,杜佳乐,等.典型城市区与森林区空气负氧离子特征比较分析[J].气象科技,2014,42(6):1083-1089.
[3] 金琪,严婧,杨志彪,等.湖北春季大气负氧离子浓度分布特征及与环境因子的关系[J].气象科技,2015,43(4):728-733.
[4] 黎勋,魏建军,王玮.广西负氧离子浓度的变化特征分析[J].气象研究与应用,2019,40(3):98-101.
[5] 袁相洋,孙迎雪,田媛,等.北京市不同功能区空气负氧离子及影响因素研究[J].环境科学与技术,2014,37(6):97-102.
[6] 蒙丽娜,孙迎雪,李科,等.北京香山空气负氧离子垂直变化测量研究[J].城市环境与城市生态,2014,27(1):12-15.
[7] 彭贵康.雅安市近地面空气负(氧)离子状况初探[J].高原山地气象研究,2012,32(1):67-72.
[8] 谭静,陈正洪,罗学荣,等.湖北省旅游景区大气负氧离子浓度分布特征以及气象条件的影响[J].长江流域资源与环境,2017,26(2):314-323.
[9] 赵蕾,吴坤悌,陈明.海南省主要景区负氧离子浓度分布及预报方程研究[J].安徽农业科学,2016,44(29):189-191,208.
[10] 王云,金素文,陈菁菁,等.安徽省空气负氧离子浓度数据的质量控制及其特征分析[C]//第34届中国气象学会年会S9大气成分与天气、气候变化及环境影响论文集.北京,2017:11.
[11] 刘佳明,刘君,李镜玉,等.古田会址旅游景区空气负离子浓度变化特征与气象因素分析[J].防护林科技,2019(6):45-47,92.
[12] 张灵杰.温州市负氧离子浓度分布与预测模型[J].自然科学,2020,8(6):569-580.
[13] 胡猛,陈蝶聪,任文斌.揭阳县空气负氧离子浓度的时空特征分析[J].广东气象,2021,43(1):53-56.
[14] 黎勋,魏建军,蒋冬雁,等.大气负离子观测站的结构原理和常见故障维修[J].气象水文海洋仪器,2021,38(1):118-120.
[15] 王玮,黎勋,苏禹宾.石油平台自动气象站运行稳定性分析[J].气象研究与应用,2020,41(3):94-97.